1. After the system is installed, it will not be activated in the winter of the year. If the indoor temperature is lower than 5°C, all the water compressors in the system should be blown out to prevent the system from freezing;
2. The initial heating (operation and commissioning) should be carried out under the guidance of the company's technical staff, and it is strictly prohibited to put it into use without commissioning;
3. The water supply temperature of the low-temperature hot water floor radiant heating system should be 35-50℃, and should not exceed 60℃, and the working pressure of the heating system should not exceed 0.8MPa;
4. When the user activates the geothermal heating system every winter, he must strictly follow the prescribed heating program to circulate and gradually, and cannot heat up in one step;
5. The user can clean the filter at the front end of the water separator before use every year to ensure the cleanliness of the water pipe and prevent the pipeline from clogging. Clean and clean the filter, check whether the filter is damaged or blocked. If it is damaged, replace it with a filter of the same specification and install it as it is;
6. When the floor heating system starts to supply water or use, air may accumulate in the pipeline, which affects the heating effect. At this time, the air release valve of the sub and water collector can be opened to discharge the gas, and the method is the same as that of traditional heating;
7. The floor heating pipe laid under the ground is only about 3-4cm away from the floor surface. It is easy to damage the floor heating pipe by smashing and knocking the ground. Therefore, it is strictly forbidden to knock, hit, etc. on the ground where the floor heating pipe is laid, and it is strictly forbidden to wedge any sharp objects to prevent damage to the floor heating pipes. It is strictly forbidden to make the ground bear a load of more than 2 tons/m2;
8. It is strictly forbidden to place a high temperature heat source near the distributor and water collector and on the ground where the floor heating pipe is laid to prevent damage to the pipeline system;
9. When the geothermal heating system is not activated in winter, attention should be paid to protection to prevent the parts of the water distributor from freezing and cracking or the water in the heating pipe from freezing;
Effect picture
Effect picture
10. If the user encounters problems such as no heat or water leakage during use, please contact the floor heating installation company in time.